Manufacturing test

PROTIME Digital Earth leakage relay senses the Earth leakage current for any equipments using 12 bit digital technology. It checks the CBCT initially & if found healthy, will monitor leakage Current & energieses relay when current goes out of the range selected. The range of tripping & Time delay is user programmable on Display. Digital Earth leakage Relays are flexible for user to decide the Auto/manual RESET of relays. It also has an option of RS232/485 Connectivity or Analog Signal proportional to Fault Current value in terms of 0-5V. For more technical data please refer BROCHURE section (DS N96D-ELR)
Digital Earth Leakage Relays-N96D Seri

INR 4500

VIEW DETAILS
PROTIME’s N22-ELR senses the Earth leakage current through CBCT. Theseleakage current if continues, can cause insulation breakdown  resulting Earth fault, which results in to loss of life or damage to equipment. PROTIME N22-ELR energises / denergises an internal relay based on Mode of operation selected by user (i.e. Normal or Fail Safe) when Leakage current goes out of the range selected on the dial. PROTIME-Earth Leakage Relays are provided with user selectable two Tripping Ranges, and also two Time delay ranges in one unit. The  CBCT  is connected externally with the Busbar or cable carrying load current passed through it. For more technical data please refer BROCHURE section (DS N22-ELR)
Earth Leakage relay- N22 Series

INR 2240

VIEW DETAILS
PROTIME's  EFR96-1C  relay is one of the most economic EFR with robust built in market. EFR96-1C senses Earth fault current for any equipment like L.T Panels Switch boards, Generators, Motors, Transformers, etc. The Fault current if goes above the selected range on the current dial, the relay energises after the time delay selected on the Time dial. The CT is to be connected externally as per diagram. The 'Test' button provides facility to stimulate the fault condition & thus checks the system tripping.The 'Reset' button provides manually resetting the relay. When link between A/M terminals is connected. Auto/ Manual Reset:MANUAL RESET: Connect link between Auto/Man terminals. AUTOMATIC RESET: Open the link between Auto/Man terminals. For more technical data please refer BROCHURE section (DS EFR96)
Earth Fault Relays-Series 96-1C

INR 1900

VIEW DETAILS

Filter using tags

DC Earth Leakage RelayEFR with Fault current status indicatorCBCT-ELRelectrical power test Kits, CT test benchrelay test kits, CITS, current injection test setDC Earth Fault RelayELR with Fault Current Status IndicatorFCBFloat cum Boost battery chargerDigital FCB Charger24V10A FCBDIGITAL PROLOGICNew